in combination with a safe elevator control system or evaluation unit (SAFEBOX), safety functions up to SIL3 can be fullfilled

| Dimensions | L x W x H / 300 x 120 x 40 mm |
| Weight | 760 g |
| Material of housing | Aluminium |
| Connector for SCA-Signals | WAGO-713-1424/116-000 |
| Supply voltage (nominal) | 24VDC |
| Residual ripple | <100mVpp |
| Supply voltage range | 10VDC … 30VDC |
| Current consumption | 35 mA @ 24 V |
| Safety of power supply | SELF/PELV |
| Connection for floor sensor | not available separately |
| DZO-Rating | Vcc - 5 V ... Vcc; 400 mA up to 40 °C; 300 mA at 40 ... 70 °C |
| Interface | RS-485; 115200 bps; 8 data bits; no parity; 1 stop bit; no flow control |
| Storage temperature | -25 ... +85 °C |
| Operation temperature | -20 ... +70 °C |
| Humidity | max. 95 %, non-condensing |
| Protection class | IP43 |
| Interference emission / immunity | EN 12015 / EN 12016 |
| Vibration / shock resistance | EN 60068-2-6 EN 60068-2-27 |
| Max. operation height above sea level | 4000m |