in combination with a safe elevator control system or evaluation unit (SAFEBOX), safety functions up to SIL3 can be fullfilled
Measuring principle: | absolute |
Measurement: | linear |
Maximum measuring length | 262 m |
Speed: | max. 10 m/s (higher speeds on request) |
Resolution: | 0.0625 mm |
Repeat accuracy: | ±1 Increment |
System accuracy in µm at 20°C: | ±(1000 + 100 x L) L = measuring length in meter |
Distance from sensor to magnetic tape | 4 mm |
Dimensions (without cable): | L x W x H = 355 x 85 x 48 mm |
Housing material: | aluminium |
Connection: | 5-pin M12 round connector |
Sensor cable: | 2 m, 3.2 m and 5 m standard cable length (others upon request) |
Weight: | approx. 900 g without cable (cable approx. 60 g/m) |
Required magnetic tape: | AB20-80-10-1-R-D-15-BK80 |
Supply voltage: | + 18 … 29 VDC (stabilized) in dual-channel operation + 10 … 18 VDC (stabilized) in single-channel operation You must use a power supply with Safety Extra Low Voltage (SELV) or Protective Extra Low Voltage (PELV). |
Residual ripple: | < 100 mVpp |
Reverse voltage protection: | integrated |
Power input: | max. 200 mA @ 24 VDC without loading the output for the door zone indication |
Interfaces: | RS-485 |
Protection of the outputs/ interfaces: | RS-485 output: short-circuit-proof output door zone indication: short-circuit-proof to GND, but not to +24 V |
Cable length: | according to EIA RS-485 specifications |
Maximum operating time: | 20 years, reduced depending on ambient conditions |
Storage temperature: | -20 °C … +85 °C |
Operation temperature: | -20 °C … +70 °C standard version -20 °C … +75 °C extended requirements Note that these specifications for both versions only apply up to an operating altitude of 2000 m above sea level. Above this limit, the maximum ambient temperature is lower due to the lower cooling capacity of the ambient air. |
Humidity: | max. 95 %, non-condensing |
Protection class: | IP54 (according to EN 60529) |
Operation height: | max. 3000 m absolute altitude standard version max. 4000 m absolute altitude extended requirements |
EMC transient emission/immunity: | according to EN 12015 / EN 12016 |
Vibration/shock resistance: | according to EN 60068-2-6 / EN 60068-2-27, EN 60068-2-29 |