LIMAX 33CP

Current all-in-one housing sensor
LIMAX 33CP
About
LIMAX 33CP

Absolute position detection and safety monitoring in one housing incl. eSGC (electronic safety gear activator)

  • Measuring height up to 262m
  • Operation speed up to 10 m/s
  • CAN/CANopen Interface
  • Available with or without eSGC Activator
  • Sensor cable with 3 or 5 m
  • User defined parameter setting

NEWLY AVAILABLE WITH AUTOMATIC UCM

No items found.

Mechanical data

Measuring principleAbsolute
Repeat accuracy±1 increment
System accuracy in µm at 20°C±(1000 + 100 x L) L = measuring length in meters
Distance sensor / magnetic tapethe correct distance is guaranteed by guidance
Basic pole pitch8 mm
Sensor housing materialaluminium
Sensor housing dimensionsL x W x H = 354 x 135 x 54 mm
Necessary magnetic tapeAB20-80-10-1-R-D-15-BK80
Maximum measuring length262 m
Connections2 outlets with open wire ends for PIO and SCA cables
(plug connectors on request)
M12 4 pole male for eSGC; according to ICE61067-2-101
Sensor cable (PIO, SCA)standard length: 3.0 m (others on request)
Weightapprox. 1400 g without cable; cable: approx. 60 g per meter

Electrical data

Supply voltage 18[1] ... 30[2] VDC (stabilized). A SELV/PELV power supply must be used
Residual ripple< 100 mV
DZO rating+ 24 VDC −20 %, max.200 mA (PNP)
Reverse polarity protectionintegrated
Power inputmax. 600 mA at 24 VDC
InterfacesCAN: CANopen DS406 or DS417
Digital input voltage18 … 30 VDC for high level; open for low level
Relay contact rating
OC, SR1, SR2
·         0...230VAC (max. 250VAC), max. 2A
·         24VDC (max. 30VDC), max. 1A
·         48VDC (max. 53VDC), max. 600mA
·         110VDC (max. 120VDC), max. 250mA
each with a resistive/inductive load with L/R < 40 ms
Rating for external supply
of SGC-actuator
24 VDC, min. 18 V; max. 30 V;
constraints for connected trip coil to be observed

Environmental conditions

Storage temperature−25 … +85° C
Operation temperature−20 … +65° C
Humiditymax. 95 %, non-condensing
Protection classIP54 (according to EN60529), higher on request
Interference emission / immunity EN 12015 / EN 12016
Vibration / shock resistanceEN 60068-2-6 / EN 60068-2-27, EN 60068-2-29
Others
Maximum operating time20 years
Safety relay contact reaction time< 55 ms
Solid state contact (eSGC) reaction time< 45 ms